Reverberation Rooms
Reverberation Rooms are designed for the determination of sound power output of noise sources, transmission loss of partitions, insertion loss of silencers, response characteristics of microphones, and random incidence absorption coefficients of materials. They are also used for high-intensity noise-level fatigue testing of aircraft, space vehicles, and other equipment.

Reverberation Rooms are designed not only to fully satisfy reverberation requirements, but also meet specific interior acoustic sound levels and other environmental requirements. In addition, rooms are tailored to provide suitable working spaces, sizes and types of doors, lighting and electrical systems, climate controls, as well as RF shielding appropriate to the work intended.

All these elements are assembled within an engineered modular structural framework Reverberation Room.

Preferred Minimum Room Volume as a function of Lowest Frequency Band of Interest*

Lowest Frequency Band of Interest Room Volume

Ft3 M3
125 Hz Octave or 100 Hz one-third octave 7062 200
125 Hz one-third octave 5297 150
160 Hz one-third octave 3531 100
250 Hz octave or 200 Hz one-third octave or higher 2472 70

*From ANSI S1.21-1972 American National Standard Method for the Determination of sound Power Levels for Small Sources in Reverberation Rooms.

Envirotech is the pioneer and leading company in the design, construction, and commissioning of modular reverberation rooms.
Reverberation Rooms is also known as ,Reverberation Chamber,Reverberation Method,Reverberation Room Method,Reverberation Room Design 

 

<< Back



 
 


Contact Details
B-1A/19, 1st Floor, Commercial Complex, Sector-51,Noida - 201307, Uttar Pradesh, India
Phone:91-120-4337633/4224633/4224644/ 2482503/2482838
Fax:91-120-4337439
Send Mail  
Contact Now
Key Personnel
Mr. Sanjeev Saraswat
Mobile:+919810319823, +919311011130, +919811011131